Product details
Specially designed for fire engines | Temperature sensor 825 in scope of delivery |
Automatic battery regeneration | Electronics moisture protected |
Product description
Details
- Charging programs no. 5, 6, 7, 8 and 9 (start, gel, AGM, acid) adjustable to battery type
- Excellent charging technology
- Fully automatic continuous operation for constant readiness of the batteries
- Charging voltages are free of peaks and regulated to eliminate overcharging
- Trouble-free operation and co-supply of the devices connected to the vehicle electrical system
- 1 main charge output and 1 additional secondary charge output "S" for back-up and trickle charging, e.g. of another starter battery of the same voltage (max. 2A)
- Starter battery is also charged with full charge current if required (short vehicle standing time)
- Message output (MA) +86 for engine start inhibit in case of vehicle mains connection
- Visual and audible warning of battery and operating faults
- Precise battery temperature compensation, temperature sensor included in scope of delivery
- Automatic battery regeneration during long idle periods (twice a week)
- Compensation of voltage losses on the charging cables for exact compliance with charging voltages
- Disconnection of batteries in case of mains failure, overheating, malfunction (safety switch per charge output)
- Power supply function allows consumers to continue operation and data retention e.g. when changing batteries
- Manual charge start in case of deep discharged battery according to DIN 14679
- Variable installation position
- Electronics protected against moisture
- Intelligent microprocessor control takes into account simultaneous supply of consumers to the battery
- Mains/charging power can be reduced in case of low power or limited mains supply (power limit function)
- 5 "MOTOR": Charging program for lead-acid/wet batteries, characteristic IU1oU2oU3: Characteristic similar to alternator/generator for moving (mobile) use (acid stratification) with particularly low maintenance (battery gassing, water consumption). Charging and charge maintenance of starter batteries in emergency vehicles, according to a conventional proposal of the Fire Service Standards Committee (FNFW). For conventional standard starter batteries, starter batteries "Absolutely maintenance-free", "Maintenance-free according to EN", "Maintenance-free according to DIN", "Maintenance-free", "Low maintenance".
- 6 "L": Closed acid/wet batteries with water consumption: L = low according to DIN EN 50342-1, characteristic curve IU1oU2oU3. Characteristic with medium U1 level for acid batteries in vehicle-mounted or external chargers with a fixed location.
- 7 "VL": Closed acid/wet batteries with water consumption: VL = very low according to DIN EN 50342-1, characteristic IU1oU2oU3. Characteristic curve with high U1 level for acid batteries in vehicle built-in or external chargers with fixed location.
- 8 "Non-woven": Sealed batteries (VRLA) with AGM/non-woven technology: characteristic IU1oU2oU3. Characteristic for AGM batteries in vehicle-mounted or external chargers with fixed location.
- 9 "Gel": Sealed batteries (VRLA) with gel technology: characteristic IU1oU2oU3. Characteristic curve for gel batteries in vehicle-mounted or external chargers with fixed location
- BR: Automatic battery regeneration
- DC: Power supply function (battery replacement)
- FB: Remote control/display connection
- PL: Power limit function (mains charging power reduction)
- TK: Temperature compensation TS Temperature sensor included in delivery
- Electronics moisture-proof
- Rated voltage (AC) in [V] 230
- Operating voltage range (AC) in [V] 190 - 265 (full charging power)
- Power consumption (AC) in max. [W] depending on version
- Sinusoidal power factor correction (CosPhi = 1): yes
- Secondary charge output "S" in [A]: 2
- Charging characteristic: IU1oU2
- Voltage limitation for all charge modes/programs [V] depending on version
- Voltage ripple in [mV] rms depending on version
- Number of charge outputs: 1 + S + MA
- Device mounting position: any
- Temperature range [°C]: -20 to +45
- Degree/class of protection: I / IP 21
- Dimensions (W x H x D) incl. mounting flanges, without connections: 305 x 90 x 265 mm
- Ambient conditions, humidity: max. 95% room humidity, non-condensing
- when vehicles are not in use for >24 hours, according to DIN 14679
- Power cable
- 1 temperature sensor
- Operating instructions
Features
Type battery | Charger |
Weight | 3900 g |
Design | VAC 2440 F 2A |
Battery capacity | 66 - 200 (400) Ah |
Charging current | 40 A |
Output | 1380 W |
ean | 4250683600509 |
Manufacturer Article No. | 0498 |
Note
Please note: since our deliveries may contain batteries (single-use and rechargeable),
according to the German Law on Batteries (BattG) we must advise you of the following:
single-use and rechargeable batteries must not be disposed of along with domestic waste, but rather you are legally required to return used batteries. Used batteries may contain damaging substances which, if not stored or disposed of appropriately, may damage the environment or your health. Batteries may, however, also contain important raw materials, such as, for example, iron, zion, magnesium or nickel, which can be recycled. Once used, you may either send the batteries back to us, or return them in
your vicinity (e.g. at the shop, communal recycling points or at our expedition warehouse) - free of charge. When returning used batteries to points of sale, the quantity you are allowed to return is limited to the quantity typical for a single end user, and to those batteries which the seller offers or used to offer in their product range.
The symbol with a rubbish bin crossed out means that you must not dispose of single-use and rechargeable batteries
along with the domestic waste. Underneath this symbol you will also find the following symbols which have the following
meanings:
Pb: battery contains lead
Cd: battery contains cadmium
Hg: battery contains mercury
Return address:
Fritz Berger GmbH
Fritz-Berger-Str. 1
D - 92318 Neumarkt