Votronic VAC 1260 M 3A Automatic charger 12 V 60 AVotronic VAC 1250 M 3A Automatic charger 12 V 50 AVotronic VAC 1240 M 3A Automatic charger 12 V 40 A
Availability:
Available in 10-14 working days
Availability:
Sold out
Product details
Specially adapted to emergency vehicles | 8 loading programs adjustable |
Battery capacity adjustable | Electronics moisture protected |
Product description
Fully automatic battery charger with 3 charging outputs for special vehicles, rescue vehicles, emergency vehicles and fire engines.
Details
Details
- Charging programs No. 1, 2, 3 and 5 (Gel, AGM, Acid, Start) and 4x Lithium-LiFePO4 adjustable to battery type
- The charging voltage is free of peaks and regulated to prevent overcharging of the batteries.
- Fully automatic continuous operation: the charger can be constantly connected to the battery and keeps it at full charge. In case of power failure, the batteries are not discharged (disconnected by safety switch).
- Lithium LiFePO4- Maintenance, Auto Wake Up, Maintenance Phase: Regular automatic activation of battery cell balancing every 10 days to ensure full battery charge throughout.
- Lead-acid battery regeneration twice a week during long idle periods to prevent harmful acid stratification.
- Parallel and buffer operation: in case of simultaneous consumption, the battery continues to be charged or maintained full. The charger automatically calculates and monitors the adjustment of the charging times.
- monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short-circuit, reverse polarity, malfunction and battery back-discharge by electronic cut-off up to complete disconnection of charger and battery by built-in safety switches.
- Connection for battery temperature sensor (temperature sensor 825 included in delivery): For lead batteries (acid, gel, AGM), the charging voltage is automatically adapted to the battery temperature, causes a better full charge of the weaker battery in cold weather, in summer temperatures, unnecessary battery gassing and thus battery stress is avoided.
- For LiFePO4 batteries, the battery temperature sensor is required for the device function: It serves to protect the battery at high and especially at low temperatures below 0°C.
- Silent Run function: Noise-optimized operation at the push of a button (night operation).
- Power supply function: Enables the supply of consumers without battery (e.g. in case of battery change).
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated.
- Built-in on-board power supply filter: Problem-free parallel operation with solar systems, wind and gasoline generators, alternators, etc. on one battery.
- Electronics moisture-protected
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support of the battery with consumers possibly still switched on.
- Built-in charging current distributor with 2 main charging outputs, both with max. current and power capacity
- In case of mixed operation with 1 supply and 1 starter battery, a separate starter charging program can be set on the built-in charging current distributor
- Starter battery is also charged with full charge current if required (short vehicle service life)
- Separate auxiliary charge output "S" for support and maintenance charging of another starter battery or as signal output +86 for engine start inhibit when vehicle is connected to mains supply
- Equalization function (IUIU charging characteristic can be activated manually for cell equalization charging)
- Battery capacity can be set 4 times (total of 12 charging programs)
- Inputs for voltage sensor (sense) lines, optionally usable with overlong charging lines and/or external, lossy diode charging current distributors
- Mains/charging power can be reduced in case of low-power or limited mains supply, e.g. weakly fused shore power, generator operation, etc. (power limit function)
- Disconnection of batteries in case of mains failure, overheating, malfunction (safety switch per charge output)
- Variable installation position
- 1 Gel": Charging program for gel batteries, characteristic IU1oU2oU3: Tuned to sealed, gas-tight gel/dryfit batteries with fixed electrolyte, which generally require a higher charge voltage level and longer U1 holding times to achieve short charge times with particularly high capacity storage and to avoid long-term battery "starvation".
- 2 "AGM": charging program for AGM/non-woven batteries, characteristic IU1oU2oU3: Intended for charging sealed, gas-tight AGM (Absorbent-Glass-Mat) batteries in lead-fleece technology, which require a particularly high U1 level with coordinated holding times for full charging and then a moderate U2 level for charge retention (plate and round cell technology).
- 3 Charging program 3 "DIN 0510" for lead-acid/wet batteries, characteristic IU1oU2oU3: General DIN characteristic for charging and charge retention of open and closed lead-acid batteries with removable cell plugs and the possibility of acid level control and acid level correction (maintenance). Also applicable for closed batteries low maintenance, maintenance free, low antimony, silver alloy, calcium etc. with low or very low water consumption. Provides with high U1 level short charging times, high charging factor and high acid mixing, even in dormant (stationary) use (acid stratification) for "wet" traction, lighting, solar, heavy duty and standard batteries.
- 5 "MOTOR": charging program for lead-acid/wet batteries, characteristic IU1oU2oU3: characteristic similar to alternator/generator for moving (mobile) use (acid stratification) with particularly low maintenance (battery gassing, water consumption). Charging and charge maintenance of starter batteries in emergency vehicles, according to an earlier proposal of the Fire Service Standards Committee (FNFW). For conventional standard starter batteries, starter batteries "Absolutely maintenance-free", "Maintenance-free according to EN", "Maintenance-free according to DIN", "Maintenance-free", "Low maintenance".
- Li "LiFePO4": Charging program for lithium batteries, characteristic IU1oU2oU3: Charging programs adapted to lithium LiFePO4 batteries with own BMS and prescribed or built-in protective circuit. A special resting maintenance function automatically keeps the LiFePO4 battery at a charge level of 50-80% when the vehicle is parked (seasonal operation), which is beneficial for its service life, and also buffers 12 V consumers and the vehicle starter battery.
- BR: Automatic battery regeneration
- DC: Power supply function (battery replacement)
- Equ: Equalization function (cell equalization charge)
- FB: Remote control/display connection
- Kap: Battery capacity (size) adjustable
- LV: Charge current distributor for one or more batteries
- PL: Power limit function mains/charging power reduction
- SR: Silent Run function (night reduction)
- TK: Temperature compensation
- TS: Temperature sensor included
- VF: Voltage sensor (for very long charge leads)
- Electronics moisture-proof
- Mains voltage (mains frequency 45 - 65 Hz) 110 V - 230 V
- Mains function voltage range, all types 85 V - 270 V, briefly 305 V (5 sec.)
- Mains voltage range for full charging power 190 V - 270 V
- Mains power consumption max.: depending on type (see the operating instructions)
- Mains current consumption (AC) max.: 5.2 A
- Active sinusoidal power factor correction (CosPhi < = 1): yes
- Charging current approx. at 110 V mains voltage: depending on version
- Switch "AC Power Limit", limitation of the mains current consumption / power depending on the version (see the operating instructions)
- Charging outputs batteries "A" + "B":
- Nominal battery voltage lead acid/LiFePO4 battery 12 V / 12 V-13.3 V
- Battery capacity adjustable (A or A+B total) depending on version
- Charge current I-phase (A, B or A+B) max. depending on version
- Charge/buffer/load current, regulated U1, U2, U3 phase 0 A - 40 A
- Automatic charge current distributor batteries A / B: yes
- Minimum battery voltage for start of charge: 0 V
- Pre-charge current, deep discharge batteries 0 V - 8 V depending on the version (see the instruction manual)
- Reverse current from battery (mains failure) < 0.2 mA
- Reset voltage (30 sec), battery type dependent: 12.75 V / 13.25 V
- Charge voltage limit (protection of connected loads): 15.0 V
- External overvoltage cut-off (20 sec): 15.5 V
- Voltage ripple: < 40 mV rms
- Charge timer: 4-fold
- Reverse polarity/short circuit/back discharge/safety protection: yes
- Safety timer per charge phase I-/U1-/U2-: yes
- Sense" inputs, for "-" battery and "+A", "+B": yes
- Lead battery regeneration for long standing time, 2x weekly 1 h: yes
- LiFePO4-Auto Wake Up at long standstill, 10 daily 0,5 h: yes
- or LiFePO4-Lithium rest maintenance (seasonal operation): yes
- Manual lead-acid equalization, Equalization, switch "Cap."-charge current depending on the version (See the manual)
- Equalization, charge voltage/charge time limit max. 16,0 V / 1,5 h
- Main charge output battery "A" (Master):
- Selectable charging programs lead-gel/AGM/acid, LiFePO4: 8
- Charge/buffer/load current, regulated IU1oU2oU3 phase depending on the version (See the user manual)
- Input for battery temperature sensor: yes
- Power supply operation (e.g. continued supply during battery change): yes
- 2. Charging output battery "B" (built-in charging current distributor, switchable):
- Charging programs optionally same as battery "A" Master: yes
- or charging program for vehicle (lead) starter battery: yes
- Charge/buffer/load current, regulated IU1oU2oU3 phase depending on the version (see the manual)
- Input for battery temperature sensor "B": yes
- Power supply operation (e.g. continued supply in case of battery change): yes
- 3. Next to charge output "C" (signal output mains):
- Nominal battery voltage (lead): 12 V
- Charging current or load capacity as signal output: 0 A - 2 A
- overcharge / reverse polarity / short circuit / reverse discharge / safety protection: yes
- Connection for remote control Automatic Charger: yes
- Device mounting position: any
- Temperature range: -20/+45°C
- Speed-controlled, temperature-controlled fan: yes
- Gradual reduction of charging power in case of overtemperature: yes
- Safety shutdown in case of overheating: yes
- Fan noise reduction, night operation (Silent Run): yes
- Protection class / protection type: I / IP21
- Dimensions, incl. mounting flanges (W x H x D): 160 x 72 x 305 mm
- Ambient conditions, humidity max. 95 % RF, non-condensing
- For further technical data please refer to the operating instructions
- Power cable
- 2 temperature sensors
- Instruction manual
Features
Type battery | Charger |
Design | VAC 1260 M 3A |
Weight | 2500 g |
Battery capacity | 110Ah - 660Ah |
Charging current | 60 A |
Output | 1020 W |
ean | 4250683615695 |
Manufacturer Article No. | 0430 |
Features
Type battery | Charger |
Design | VAC 1250 M 3A |
Weight | 2450 g |
Battery capacity | 88Ah - 550Ah |
Charging current | 50 A |
Output | 840 W |
ean | 4250683615688 |
Manufacturer Article No. | 0427 |
Features
Type battery | Charger |
Design | VAC 1240 M 3A |
Weight | 2400 g |
Battery capacity | 75 Ah-480 Ah |
Charging current | 40 A |
Output | 680 W |
ean | 4250683615671 |
Manufacturer Article No. | 0413 |